Service
Transformer repair & rewinding
Rewinding and repair of all kinds of transformers, whoever made them.
01What we see most
Sound familiar?
- Burnt or shorted winding
- A smell of burning, visible charring, or the unit tripping its protection as soon as it is energised.
- Low or unstable output
- Output voltage sitting below where it should, or wandering under load.
- Overheating
- Running far hotter than usual, or oil temperature climbing where it did not before.
- Noise
- A hum that has changed in character, or rattling from the core.
02About the work
What to expect.
We rewind and repair all kinds of transformers, regardless of who built them. A transformer that has failed is usually worth repairing rather than replacing, and the same workshop that manufactures our own units does the repair work.
Bring the unit to whichever outlet is nearest you, or call and describe the fault first if you are not sure it is worth moving.
We do not promise a turnaround time before seeing the unit. Ask us when you bring it in and we will tell you honestly.
03Process
How it works.
Describe the fault
Call, message or send photos before moving a heavy unit.
We inspect
The unit comes to the workshop and we find what actually failed.
We quote the repair
You decide before any work starts.
Rewind and reassemble
Then testing, then hand-over.
—Case study
All our work“I send them anything with a winding in it. What I value is the report that comes back — what failed, why, and what they changed — so I can tell my client straight.”
Sample content — replace before launch
From the bench · Transformer rewinding
A lightning-struck 100 kVA, back on the pole
An oil-cooled distribution transformer took a strike in a spring storm. We stripped, rewound and tested it rather than scrapping the tank.
- Rating
- 100 kVA
- Tested
- Ratio + IR
- Windings
- HV + LV rewound
Sample content — replace before launch
Winter voltage up here is a lottery. The transformer they built for our kitchen and laundry load has not missed a beat through two seasons of snow.
04From the catalogue
Or buy new.
Single Phase · Dry type
Dry Type Single Phase 110-Input Transformer
5–10 kVA · 3 ratings · 110 V input
from
₹20,000
2027–28 price
Single Phase · Oil-cooled
Oil Type Single Phase 110-Input DL Transformer
5–25 kVA · 7 ratings · 110 V input
from
₹24,600
2027–28 price
Single Phase · Oil-cooled
Oil Type Single Phase 90-Input Transformer
5–25 kVA · 7 ratings · 90 V input
from
₹30,000
2027–28 price
Three Phase · Dry type
Three Phase Dry Type 110-Input Transformer
7.5–30 kVA · 6 ratings · 110 V input
from
₹59,000
2027–28 price
Three Phase · Oil-cooled
Three Phase Oil Type 90-Input Transformer
7.5–400 kVA · 21 ratings · 90 V input
from
₹72,000
2027–28 price
Three Phase · Toroidal · Copper
Toroidal Coil Three Phase 110-Input Transformer (Copper)
10–100 kVA · 12 ratings · 110 V input
from
₹65,000
2027–28 price
Three Phase · Toroidal · Aluminium
Toroidal Coil Three Phase 110-Input Transformer (Aluminium)
10–100 kVA · 12 ratings · 110 V input
from
₹60,000
2027–28 price
05Questions
Asked often.
How does transformer repair & rewinding work at Paramount Electricals?
1. Describe the fault — Call, message or send photos before moving a heavy unit. 2. We inspect — The unit comes to the workshop and we find what actually failed. 3. We quote the repair — You decide before any work starts. 4. Rewind and reassemble — Then testing, then hand-over.
What do you need to know to quote for transformer repair & rewinding?
Rating in kVA and the make, if you know it. What it is doing — or not doing. When it started, and what changed around then. Which outlet is nearest you. With these, we can usually quote without seeing the unit.
What faults do you see most?
Burnt or shorted winding — A smell of burning, visible charring, or the unit tripping its protection as soon as it is energised. Low or unstable output — Output voltage sitting below where it should, or wandering under load. Overheating — Running far hotter than usual, or oil temperature climbing where it did not before. Noise — A hum that has changed in character, or rattling from the core.
How long will it take?
We do not promise a turnaround time before seeing the unit. Ask us when you bring it in and we will tell you honestly.
Do you repair transformers and motors you did not make?
Yes. Rewinding and repair of all kinds of transformers and motors is core work for us, whoever the original maker was.
Where are you located?
We have outlets at Maisuma Bazar in Srinagar, at Jalalabad, Sujwan in Jammu, and in Leh, plus our own factory at Sathu Payeen, Barbar Shah in Srinagar.
06Guides
Read before you decide.
- Transformers · 2 min readDry-type or oil-type: choosing how a transformer is cooledHow dry-type and oil-type transformers get rid of heat, where each one fits best, and the practical points — space, fire risk, upkeep — that usually decide it.
- Transformers · 1 min readCopper or aluminium windings: what actually changesBoth metals make good transformer windings. Here is what differs — conductivity, size, weight and cost — and what to ask when comparing the two.
- Basics · 2 min readHow to read a motor or transformer nameplateWhat the figures on a motor or transformer nameplate mean — rating, voltage, current, speed, phase, frequency — and which ones to send when asking for a quote.
- Basics · 2 min readLooking after transformers and motors through a hard winterWhat cold, damp and heavy heating loads do to transformers and motors in a hard winter, and the simple checks that keep them running until spring.
Tell us the rating. We’ll price it.
A kVA or HP figure and what the job is — that is enough to start.
